double inlet forward curve centrifugal fan used in industry exhaust
1. An Overview of Dual Inlet Forward Centrifugal Blowers
(1)Description
Dual Inlet Forward Centrifugal Blowers are designed for use where space limitations are a problem. The impellers are permanently mounted to the external rotors for ease of installation and maintenance-free operation. These units may be mounted in any orientation for effective air movement. Optional configuration includes different size scroll housing and impellers mounted on either end of the motor, airflow aimed at any angle and various output characteristics.
(2)Product Features
1. Material: Housing: galvanized sheet steel
Impeller: galvanized sheet steel
Rotor: Coated in black
2. Bearings: Maintenance- free ball bearings
3. Direction of rotation: Clockwise, seen on rotor
4. Approvals: all models have reached UL approval, CE approval and CCC approval
5. The protection of motors: all models are fitted with an internal Thermal Overload Protection Device
6. Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request (Any)
7. Insulation classes: class B and class F
(3)Typical applications
Exhausting industrial processes, roof and building ventilation, cleanroom and other sensitive HEPA filtering application, laboratory and research facility ventilation, air conditioner, heat exchangers, in-line duct blowers, range hood, fire place inserts, humidifiers, dehumidifiers, hand dryers.
2. The Brief Introduction of Dual Inlet Forward Centrifugal Blower YWFD160
—Material: Housing: galvanized sheet steel
Impeller: galvanized sheet steel
Rotor: Coated in black
—Direction of rotation: Clockwise, seen on rotor
—Type of protection: IP54 or IP44
—Insulation class: B or F
—Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request(Any)
—Condensate discharges: Rotor-side
—Mode of operation: Continuous operation (S1)
—Bearings: Maintenance- free ball bearings
—Motor protection: Design with thermal overload protector
—Cable exit: variable
—Product conforming to standard: CE
—Approval: UL, CCC
3. performance parameters
Model | Voltage V | Frequency Hz | Current A | Input Power W | Speed RPM | Capacitor μF | Noise dBA | Max Air Flow m³/h | Curve |
YWF-D2E-160 | 230 | 50 | 1.8 | 400 | 1800 | 10 | 65 | 1200 | 1 |
YWF-D4E-160 | 230 | 50 | 0.83 | 185 | 1350 | 6 | 64 | 950 | 2 |
60 | 1.2 | 265 | 1410 | 6 | 65 | 830 | 3 |
4. shape and the size of installation
5. air volume and static pressure curve